| Detailed Product Description: |
|
For use in mines Rated voltage 1KV and below Copper fixed laying of PVC insulated power cables (MT818-1999)
|
|
The MVV cable, cable MVV22 -0.6 / 1 (1.5-300) mm2 Usage: for rated voltage 0.6/1KV and the following transmission and distribution lines in the coal mine.
First, use
This product is for use in mines rated voltage 1KV and below fixed laying cables, power transmission applicable to coal mine.
Second, the conditions of use
Wire core long-term allowable working temperature to 65 ° C, cable laying temperature of not less than 0 ° C, the cable allows the minimum bend radius of 15 (D + d) ± 5%.
|
|
|
Model
|
Name
|
|
MVV
|
PVC insulated and sheathed mining power cable
|
Energy transmission lines, but can not bear external mechanical forces
|
|
MVV22
|
Coal mines, steel tape armored PVC insulated PVC sheathed power cable
|
Energy transmission lines, able to bear external mechanical forces
|
|
MVV32
|
Coal with PVC insulated steel wire armored, PVC sheathed power cable
|
Energy transmission lines, can withstand a certain force
|
|
MV42
|
PVC insulated thick steel wire armored, PVC sheathed mine with power cable
|
Energy transmission lines, able to withstand greater pull
|
|
Technical Requirements:
|
Nominal cross section (mm 2)
|
Rated voltage (KV)
|
|
0.6 / 1
|
1.8 / 3
|
3.6 / 6
|
|
Insulation Nominal Thickness (mm)
|
|
1.5
|
0.8
|
-
|
-
|
|
2.5
|
0.8
|
-
|
-
|
|
4
|
1.0
|
-
|
-
|
|
6
|
1.0
|
-
|
-
|
|
10
|
1.0
|
2.2
|
3.4
|
|
16
|
1.0
|
2.2
|
3.4
|
|
25
|
1.2
|
2.2
|
3.4
|
|
35
|
1.2
|
2.2
|
3.4
|
|
50
|
1.4
|
2.2
|
3.4
|
|
70
|
1.4
|
2.2
|
3.4
|
|
95
|
1.6
|
2.2
|
3.4
|
|
120
|
1.6
|
2.2
|
3.4
|
|
|
|
Rated voltage 1KV and fixed laying of copper core XLPE insulated coal with power cables (MT818-1999)
|
|
The cable MYJV cable MYJV22, MYJV32 mine cable products in the coal mine rated voltage 0.6/1KV and the following transmission and distribution lines.
First, use
This product is for use in mines rated voltage 1KV and below fixed laying cables, power transmission applicable to coal mine.
Second, the conditions of use
Wire core long-term allowable working temperature is 90 ℃, cable laying temperature of not less than 0 ° C, the cable allows the minimum bend radius of 15 (D + d) ± 5%.
|
|
|
Model
|
Name
|
|
MYJV
|
Power Cable XLPE insulated PVC sheathed coal mine
|
|
MYJV22
|
XLPE insulated steel tape armored PVC sheathed mine with power cable
|
|
MYJV32
|
XLPE insulated steel wire armored PVC sheathed coal mines with power cables
|
|
MYJV42
|
XLPE insulated thick steel wire armored, PVC sheathed mine with power cable
|
|
Size:
|
Model
|
Number of cores
|
Rated voltage KV
|
|
0.6 / 1
|
1.8 / 3
|
3.6 / 6,6 / 6
|
6/10, 8.7/10
|
|
Nominal cross section (mm 2)
|
|
MYJV
|
3
|
1.5 to 300
|
10 to 300
|
25 to 300
|
25 to 300
|
|
MYJV22
|
3
|
4 to 300
|
10 to 300
|
25 to 300
|
25 to 300
|
|
MYJV32
|
3
|
4 to 300
|
10 to 300
|
25 to 300
|
25 to 300
|
|
MYJV42
|
3
|
4 to 300
|
10 to 300
|
25 to 300
|
25 to 300
|
|
|
MT818.13-1999 coal mine with a rated voltage of 10KV and below Copper fixed laying retardant power cable with Part 3, coal crosslinked PVC insulated power cable
|
|
|