Detailed Product Description: |
Computer Cable Product Description:
This product is suitable for rated voltage 500V and below for the anti-interference requirements for the computer connection cable and automation [1]. Ground cable core insulation K Class B low density polyethylene with antioxidant properties. Polyethylene insulation resistance and withstanding voltage, dielectric constant temperature and variable frequency of small and medium loss, not only meets the requirements of the transmission performance, and ensure that the cable life.
In order to reduce the circuit crosstalk and external interference, shielded cable structure. The cable shielding requirements are based on different occasions were used: shielded twisted pair combination of the total shielding twisted pair cable, shielded twisted pair combination after the total shielding method.
Shielding materials are round copper wire, copper strips, aluminum / plastic composite with three kinds. Shielded with the shield has good insulating properties, the cable in use shield between the shield on the potential difference will not affect the signal transmission quality.
Computer cable parameters:
Rated voltage (U0 / U): 300/500V
Long-term operating temperature of 70 ℃
The ambient temperature of not less than: fixed installation -40 ° C, fixed laying -15 ℃
Minimum bend radius: unarmored should be less than 6 times the cable diameter, with armored cable should be not less than 12 times the cable diameter
Charging DC 500V voltage test stable at 20 ° C for 1 min insulation resistance should be not less than 2500MΩ · Km
Twisted shielded and twisted pair shielded with overall shield should continue to road
50HZ, AC 2000V voltage test 5min breakdown between cable wire core and between cores and shield should be subjected to
DJYPV: polyethylene insulation and twisted pair copper wire braided shielding PVC sheath computer cable laying indoors, cable trench, pipeline requirements electrostatic shielding occasions
DJYVP: polyethylene insulated twisted pair copper wire braided shield PVC sheath computer cable laying indoors, cable trench, pipeline and other requirements of the electrostatic shielding occasions
DJYPVP: polyethylene insulation and twisted pair copper wire woven in shield and total shield PVC sheathed computer cable laying indoors, cable trench, pipeline and electrostatic shielding occasions
DJYP2V: polyethylene insulated electrostatic shield occasions twist copper shielding PVC sheath computer cable laying indoors, cable trench, pipeline requirements
With Cu: polyethylene insulation, twisted copper strip shield PVC sheath computer cable laying indoors, cable trench, pipeline and other requirements of electrostatic shielding occasions
DJYP2VP2: polyethylene insulated twisted copper tape shielding, and general shield PVC sheathed computer cable laying indoors, cable trench, pipeline and other requirements for electrostatic shielding occasions
DJYP3V: polyethylene insulation twisted plastic composite tape sub-shielded PVC sheathed computer cable laying indoors, cable trench, pipeline requirements electrostatic shielding applications
DJYVP3: polyethylene insulation, twisted aluminum compound with general shield PVC sheathed computer cable laying indoors, cable trench, pipeline and other requirements for electrostatic shielding applications
DJYP3VP3: polyethylene insulated twisted pair plastic composite tape sub-shield and total shield PVC sheathed computer cable laying indoors, cable trench, pipeline and other requirements for electrostatic shielding occasions
DJYPVR: polyethylene insulation, twisted copper wire braided shield PVC sheathed flexible computer cable laying indoor, cable trench, pipeline and other requirements for electrostatic shielding occasions
DJYVPR: polyethylene insulation and twisted pair copper wire braided shield PVC sheathed flexible computer cable laying indoors, cable trench, pipeline and other requirements of the electrostatic shielding occasions
DJYPVPR: polyethylene insulation, twisted copper wire braided shielding and shield PVC sheathed flexible computer cable laying indoors, cable trench, pipeline and other requirements for electrostatic shielding occasions
DJYP2VR: polyethylene insulated twisted copper shielding soft PVC sheath computer cable laying indoors, cable trench, pipeline requirements electrostatic shielding occasions
DJYVP2R: polyethylene insulated twisted copper strip shield PVC sheathed flexible computer cable laying indoors, cable trench, pipeline and other requirements of electrostatic shielding occasions
DJYP2VP2R: polyethylene insulated twisted copper tape shielding and shield PVC sheathed flexible computer cable laying indoors, cable trench, pipeline and other requirements of electrostatic shielding occasions
Electrostatic shielding occasions DJYP3VR: polyethylene insulation, twisted aluminum composite with a soft PVC sheath computer cable shielding laying indoors, cable trench, pipeline requirements
DJYVP3R: polythene insulation paired plastic composite tape shield PVC sheathed flexible computer cable laying indoors, cable trench, pipeline and other requirements of electrostatic shielding occasions
DJYP3VP3R: polyethylene insulation and twisted aluminum composite tape shielding and shield PVC sheathed flexible computer cable laying indoors, cable trench, pipeline requirements electrostatic shielding occasions
DJYPV22: polyethylene insulated twisted copper braided shield PVC sheathed computer cable laying indoor, cable trench, pipeline and other requirements electrostatic shielding to withstand heavier mechanical force fixed occasions
DJYVP22: polyethylene insulation installed twisted pair copper wire braided shield PVC sheathed computer cable laying indoors, cable trench, pipeline requirements electrostatic shield and fixed places to withstand heavier mechanical force
DJYPVP22: polyethylene insulation of twisted copper wire braid sub-shield and shield PVC sheathed, steel tape armored computer cable laying indoors, cable trench, pipe, and requirements for electrostatic shielding and withstand heavier mechanical force for fixed installation
DJYP2V22: polyethylene insulation require electrostatic shielding and copper belt of sub-twisted shield PVC sheathed computer cable laying indoors, cable trench, pipeline withstand heavier mechanical force fixed occasions
With Cu-22: polyethylene insulation installed on twisted copper strip shield PVC sheathed computer cable laying indoor, cable trench, pipeline and other requirements of the electrostatic shield and withstand heavier mechanical force for fixed installation
DJYP2VP2-22: polyethylene insulation installed twisted copper tape shielding and shield PVC sheathed computer cable laying indoors, cable trench, pipeline requirements electrostatic shielding to withstand heavier mechanical force fixed occasions
DJYP3V22: polyethylene insulation requirements for electrostatic shielding and twisted aluminum composite with sub-shield PVC sheathed computer cable laying indoors, cable trench, pipeline withstand heavier mechanical force fixed occasions
DJYVP3-22: polyethylene insulation requirements for electrostatic shielding and twisted aluminum composite with a shield PVC sheathed installed the computer cable laying indoors, cable trench, pipeline withstand heavier mechanical force fixed occasions
DJYP3VP3-22 polyethylene insulation, twisted aluminum composite with sub-shield and shield PVC sheathed computer cable laying indoor, cable trench, pipeline and other requirements of the electrostatic shield and withstand heavier mechanical force for fixed installation
|