KVV cable | the KVV Control Cable KVV control cable KVV cables | the KVV control cable KVV control cable details:
|
|
|
A conductor to allow long-term operating temperature of 70 ℃.
2, The ambient temperature ≥ 0 ° C.
3, the minimum bending radius:
4, unarmored cables, should be not less than six times the cable diameter.
5, with armor or copper tape screen cover structured cabling should not be less than 12 times the cable diameter.
6, screen cover flexible cable should be no less than six times the cable diameter.
7, model and name: KVV Copper conductor PVC insulated PVC sheathed control cable
KVVP conductor PVC insulated and sheathed braided shielded control cable
KVVP2 conductor PVC insulated and sheathed copper tape shield control cable
KVV22 Copper conductor PVC insulated PVC sheathed, steel tape armored control cable
KVVR Copper conductor PVC insulated PVC sheathed soft control cable
KVVRP Copper conductor PVC insulated PVC sheathed braided shield flexible control cable
KVVP-22 conductor PVC insulated and sheathed copper wire braided shield steel tape armored control cable
ZR-KVVP2-22 conductor PVC insulated and sheathed copper tape shield steel tape armored flame retardant control cable
|
Mining control cable Executive standard: MT818-1999
2, coal used to control cable use: This product is suitable for AC rated voltage U0 / U 450/750V and control monitoring circuit and protection circuit and power distribution equipment, electrical instrumentation cable.
3, for use in mines control cable to use the occasion
MKVV MKVVP MKVVRP MKVVR 0.5-10mm22-61 core is applicable to weak control system, or strong electromagnetic interference area
MKVV22 MKVV32 0.5-10mm22-61 core
Strong electromagnetic interference
4, the main technical performance and indicators
Conductor DC resistance Ω, 20 ° C / km 0.75mm 2 ≤ 24.5 1.0mm 2 ≤ 18.1 1.5mm 2 ≤ 12.1 2.5 mm 2 ≤ 7.41
20 ° C, core insulation of the cable insulation resistance MΩ.km ≥ 60
AC power frequency resistance voltage 3.0KV/5min by
Mining the characteristics of the use of cable
The conductor of the long-term allowable working temperature -40 to +50 ° C;
The average maximum relative humidity of ≤ 95 (+25 ° C)
Allow attached and installed the temperature should not exceed -10 ° C
Use characteristics: coal with long-term control of the cable conductor to allow the operating temperature of 70 ° C, cable laying temperature should be not less than 0 ℃.
Allowed bending radius of the coal used to control cable: cables with armor or copper tape shielding structure should not be less than the cable diameter
12 times. Soft cable shield structure should be not less than six times the cable diameter. Unarmored cables should not be small
6 times the cable diameter.
|
|