Product Features:
|
Mine communication cable Uses: mainly used in coal mine monitoring and control, and rail transit system for information transmission lines, communication systems can also be used for information transmission.
|
|
Mine communication cable MHYA used details:
|
|
Mine communication cable MHYA conditions of use
● Mine communication cable environment temperature: -40 ~ 50 ℃
● Mine communication cable month average maximum relative temperature: 95% (+25 ° C)
● Mine communication cable installation laying the ambient temperature: ≥ -10 ℃
● Mine communication cable installation, the minimum bend radius: 15 times MHYV, MHJYV for 10 times the cable diameter, the other models for the cable diameter
● Mine communication cable model names and the use of range
Model
|
Name
|
Use of
|
MHYV
|
Coal with polyethylene insulated PVC sheathed communication cables
|
For drift, Inclined and electromechanical Cave Room
|
MHJYV
|
Coal using enhanced line core polyethylene insulated PVC sheathed communication cables
|
For mechanical damage higher drift and Inclined
|
MHYBV
|
Coal insulated galvanized steel wire braided armored, PVC sheathed communication cables
|
For mechanical damage higher drift and Inclined
|
MHYAV
|
Mine insulated aluminum - polyethylene bonding layer PVC sheathed communication cables
|
For wet and slanted
|
MHYA32
|
Coal mine polyethylene insulated aluminum - polyethylene adhesive sheath steel wire armored, PVC sheathed communication cables
|
For shaft and inclined
|
● structural data and technical support
Model structure and performance
|
MHYV
|
MHJYV
|
MHYBV
|
MHYAV
|
MHYA32
|
Specification (logarithmic \ core number)
|
1 × 2
|
2 × 2
|
1 × 4
|
5 × 2
|
1 × 2
|
2 × 2
|
5 × 2
|
10 × 2
|
20 × 2
|
20 × 2
|
30 × 2
|
50 × 2
|
30 × 2
|
50 × 2
|
80 × 2
|
Line core structure of the root / diameter (mm)
|
7/0.28
|
4/0.28 copper
+3 / 0.28 Telegraph
|
1/0.8
|
Bonding of the sheath and armor layer
|
-
|
-
|
Weaving of galvanized wire 0.2-0.3
|
Aluminum - polyethylene tape wrapped
|
Polyethylene wrapped with galvanized steel wire armored
|
Cable outer diameter ≤ mm,
|
7.1
|
8.6
|
8.0
|
11.5
|
7.1
|
8.6
|
15.6
|
18.4
|
23.4
|
23.4
|
27.4
|
32.6
|
32.6
|
37.3
|
43.0
|
Cable Reference Weight kg / km
|
58
|
89
|
68
|
134
|
58
|
87
|
218
|
323
|
512
|
472
|
678
|
1006
|
1450
|
1943
|
2828
|
Cable conductive core is DC resistance of ≤ Ω / km
|
45
|
73
|
36.7
|
Insulated core insulation resistance ≥ Ω / km
|
3000
|
Resistance to AC voltage
|
Cable insulation wire core and the core of the insulated wire and shielding should be able to withstand lasted 1min the, 1.5kv AC voltage
|
Working capacitance ≤ μF / km.
|
0.06
|
The far-end crosstalk attenuation ≥ dB, (500m)
|
70
|
Intrinsic attenuation ≤ dB / km
|
1.10
|
1.30
|
0.95
|
DC resistance of the cable work when the difference ≤
|
Loop resistance of 2%
|
|
|
Admin>>>
You are the 534843 visitor
Copyright © GuangDong ICP No. 10089450, The first branch in Tianjin Cable Plant All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility